BlocPower - Measurement and Verification Plan
Last updated:
Executive Summary
This document outlines the measurement and verification (M\&V) methodology and data intake requirements for the electrification projects managed by BlocPower. The plan encompasses baseline establishment, metering infrastructure, data collection protocols, and savings calculation methodologies.
Evidence of Asset
BlocPower will provide evidence that will demonstrate the installation of the measure. They will also need to include the heat pump serial number on Asset upload.
Methodology Selection
We will use the Technical Specification: Quantifying energy use and emissions savings for electrification methodology.
We expect to use “From NREL ResStock SqFt-Based Load Selection (Baseline: 1.1.3.2 and Reporting: 1.1.3.2).
Data Requirements
Incorporated Data Requirements
The following are defined in the Technical Specification: Common Decarbonization methodology:
- Definitions
- Electricity Carbon Intensity Calculations
- Shared Data Intake Requirements
- Consequential Carbon Accounting Rules
- EAC Definition and Rules
- Generated Versus Avoided Emissions
User-Provided Data Requirements
The following is a static description of the required and optional fields for a given Asset. An updated CSV template with the correct column names is available here and timeseries description is available here.
Attributional Data
The following data is required in addition to what is listed in Technical Specification: Common Decarbonization methodology.
General Building Characteristics
Field | Description | Default if not provided | Required? | Use |
---|---|---|---|---|
Square Footage of Living Space | Total conditioned living area of the building in square feet | - | Y | Modeling |
Do walls have insulation? | Indicates presence of wall insulation in the building | Yes | - | Modeling |
Alternative Fuel to Electrification | Identifies the fuel type that would have been used if electrification was not implemented | Natural Gas | - | Modeling |
Building Type | Classification of building according to NREL ResStock categories | - | Y | Modeling |
Year Built | Year the building was originally constructed | - | Y | Modeling |
# of Stories | Total number of above-ground floors in the building | - | Y | Modeling |
Likely Heating Thermostat Setpoint (°F) | Expected temperature setting for heating system operation | - | - | Modeling |
Intervention
Field | Description | Default if not provided | Required? | Use |
---|---|---|---|---|
Commenced Operation Date | Date when the electrification system installation was completed and began operation | - | Y | Modeling |
Physical Serial Number | Serial number of the installed heat pump | - | Y | Verification |
Heating Backup System | Description of any secondary or backup heating system installed | - | - | Modeling |
Furnace Replacement? | Indicates if an electric furnace was installed to replace existing heating system | - | Y | Modeling |
Water Heater Replacement? | Indicates if an electric water heater was installed to replace existing unit | - | Y | Modeling |
Oven Replacement? | Indicates if an electric oven was installed to replace existing appliance | - | Y | Modeling |
Dryer Replacement? | Indicates if an electric clothes dryer was installed to replace existing appliance | - | Y | Modeling |
Pool Heater Replacement? | Indicates if an electric pool heater was installed to replace existing system | - | Y | Modeling |
Additional EE Work Done During Install? | Identifies any energy efficiency improvements made during electrification (None, Basic, Enhanced) | None | - | Modeling |
Effective Useful Life (Years) | Expected operational lifespan of installed electrification equipment | 15 | - | EAC Attribution |
Rated for Cold Climates? | Indicates if the installed equipment is rated for operation in cold climate conditions | No | - | EAC Attribution |